Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

What Air Permeability Rating Do I Need?

The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

What Does An Air Leakage Test in the UK Involve?

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.

When Should The Test Take Place?

The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.

Why E2 Consultants?

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

At E2 Consultants we offer Air Leakage Testing throughout the UK and surrounding areas. Our experienced air leakage testing consultants will also be happy to offer advice on the best ways to gain your target rating.

For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

How Many Properties Need An Air Tightness Test?

According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.

For further House-Leakage-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

» » »
House Leakage Testing
» Domestic Services » House Leakage Testing

In Area T

Domestic Air leakage testing in Tadcaster, Domestic Air leakage testing in Tadley, Domestic Air leakage testing in Tadworth, Domestic Air leakage testing in Tain, Domestic Air leakage testing in Talgarth, Domestic Air leakage testing in Tamworth, Domestic Air leakage testing in Tanwood, Domestic Air leakage testing in Tarporley, Domestic Air leakage testing in Taunton, Domestic Air leakage testing in Tavistock, Domestic Air leakage testing in Teddington, Domestic Air leakage testing in Teignmouth, Domestic Air leakage testing in Telford, Domestic Air leakage testing in Tenby, Domestic Air leakage testing in Tenterden, Domestic Air leakage testing in Tetbury, Domestic Air leakage testing in Tewkesbury, Domestic Air leakage testing in Thame, Domestic Air leakage testing in Thamesmead, Domestic Air leakage testing in Thatcham, Domestic Air leakage testing in Thaxted, Domestic Air leakage testing in The midlands, Domestic Air leakage testing in Thetford, Domestic Air leakage testing in Thirsk, Domestic Air leakage testing in Thornbury, Domestic Air leakage testing in Thornton-Clevelyes, Domestic Air leakage testing in Thrapston, Domestic Air leakage testing in Thurso, Domestic Air leakage testing in Tibberton, Domestic Air leakage testing in Tidcombe, Domestic Air leakage testing in Tidworth, Domestic Air leakage testing in Tilbury, Domestic Air leakage testing in Tillicoultry, Domestic Air leakage testing in Tintagel, Domestic Air leakage testing in Tipton, Domestic Air leakage testing in Tiverton, Domestic Air leakage testing in Tobermory, Domestic Air leakage testing in Tockenham, Domestic Air leakage testing in Toddington, Domestic Air leakage testing in Todmorden, Domestic Air leakage testing in Tonbridge, Domestic Air leakage testing in Tongham, Domestic Air leakage testing in Tonypandy, Domestic Air leakage testing in Tooting, Domestic Air leakage testing in Torpoint, Domestic Air leakage testing in Torquay, Domestic Air leakage testing in Torrington, Domestic Air leakage testing in Totnes, Domestic Air leakage testing in Tottenham, Domestic Air leakage testing in Totton, Domestic Air leakage testing in Towcester, Domestic Air leakage testing in Trafford Park, Domestic Air leakage testing in Tredegar, Domestic Air leakage testing in Tregaron, Domestic Air leakage testing in Treharris, Domestic Air leakage testing in Trentham, Domestic Air leakage testing in Treorchy, Domestic Air leakage testing in Tring, Domestic Air leakage testing in Troon, Domestic Air leakage testing in Trowbridge, Domestic Air leakage testing in Truro, Domestic Air leakage testing in Tunbridge Wells, Domestic Air leakage testing in Tutbury, Domestic Air leakage testing in Tutnall, Domestic Air leakage testing in Twickenham, Domestic Air leakage testing in Twycross, Domestic Air leakage testing in Tyldesley, Domestic Air leakage testing in Tyne, Domestic Air leakage testing in Tynemouth, Domestic Air leakage testing in Tywyn,